Removable front panels for serviceability
-
1" thick insulation
-
ECM motor with continuous low speed blower
-
Slope top for quiet operation
-
Low water flow
-
6 row water coil
-
External 3-speed Grundfos water pump (included)
-
To be compliant with most building codes, If there has not been a call for heat within a 12-hour period, the circulator will turn on for 2 minutes thus eliminating risk of bacteria.
-
Pump "Pre-charge" on a call for heat, turns pump on prior to blower in order to get warm/hot water in the coil thereby avoiding blowing cold air throughout the house
-
Blower "Scavenge" keeps the blower on after the call for heat [from t-stat] has ended so that valuable energy in the water coil is used up, not wasted
NEW - HVS High Velocity Air Handler Features
MODELS HVS600 HVS800
Dimensions 18 x 33.5 x 18.5 18 x 33.5 x 22.5
w" x h" x d"
Weight 90 lbs (41 kg) 100 lbs (45 kg)
BTU 35,000* 46,000*
*BTUs based on 140° F water temp. See installation guide to adjust BTU output.